Assessment Year | 1994 |
---|---|
Principal Product | Engine Bearings |
NAICS |
n/a
|
SIC | 3562: Ball and Roller Bearings |
Sales Range | $50 M to 100M |
# of Employees | 545 |
Plant Area |
225,000
ft2
|
Annual Production | 85,000,000
thousand feet
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $924,746 | 24,960,141 |
kWh
|
$0.037 |
Natural Gas | $201,962 | 36,499 |
MMBtu
|
$5.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,000 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,909 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,806 | $15,603 |
$2,806
47,773
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $1,312 | $29,510 |
$1,312
7,620
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $6,240 | $452 |
$6,240
176,143
kWh
|
- | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,526 | $1,000 | - |
$1,526
-
MMBtu
|
|
05 | 2.2136: Install / repair insulation on steam lines | $325 | $116 | - |
$325
-
MMBtu
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,432 | - |
$4,432
125,147
kWh
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,359 | $200 |
$3,359
94,959
kWh
|
- | |
TOTAL RECOMMENDED | $20,000 | $46,881 |
$18,149
451,642
kWh
|
$1,851
-
MMBtu
|
||
TOTAL IMPLEMENTED | $11,909 | $45,313 |
$11,909
275,499
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs