ITAC Assessment: WV0011
ITAC logo
ITAC Assessment: WV0011
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1993
Principal Product Aluminum Rolled Products
NAICS
n/a
SIC 3313: Electrometallurgical Products, Except Steel
Sales Range $10
M
to 50
M
# of Employees 220
Plant Area 277,000
ft2
Annual Production 0
units
Production Hrs. Annual 8,736
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $924,750 23,034,877
kWh
Natural Gas $349,438 79,390
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $110,481 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $62,127

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2437: Recover waste heat from equipment $2,345 $2,613 - $2,345
-
MMBtu
02 2.7491: Insulate glazing, walls, ceilings, and roofs $18,346 $6,950 - $18,346
-
MMBtu
03 2.7124: Make a practice of turning off lights when not needed $5,265 $4,110 $5,265
257,327
kWh
-
04 2.2443: Re-use or recycle hot or cold process exhaust air $27,112 $1,450 - $27,112
-
MMBtu
05 2.1311: Replace electrically-operated equipment with fossil fuel equipment $51,421 $28,120 $51,421
-
kWh
-
06 2.2511: Insulate bare equipment $551 $247 - $551
-
MMBtu
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,643 $3,362 $1,643
75,909
kWh
-
08 2.4133: Use most efficient type of electric motors $3,798 $12,730 $3,798
175,264
kWh
-
TOTAL RECOMMENDED $110,481 $59,582 $62,127
508,500
kWh
$48,354
-
MMBtu
TOTAL IMPLEMENTED $62,127 $48,322 $62,127
508,500
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs