Assessment Year | 2025 |
---|---|
Principal Product | Paper clothing |
NAICS | 313220: Narrow Fabric Mills and Schiffli Machine Embroidery |
SIC | 2241: Narrow Fabric and Other Smallware Mills: Cotton, Wool, Silk, and Manmade Fiber |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
170,242
ft2
|
Annual Production | 925
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $355,473 | 5,066,997 |
kWh
|
$0.070 | |
Electricity Demand | $214,870 | 12,502 |
kW-mo/yr
|
$17.19 | |
Electricity Fees | $56,770 | - |
|
- | |
Natural Gas | $40,586 | 13,608 |
MMBtu
|
$2.98 | |
Waste Disposal Costs | |||||
Water Usage | $3,552 | 267 |
Tgal
|
$13.30 | |
TOTAL YEARLY COSTS | $671,251 | ||||
RECOMMENDED SAVINGS* | $19,112 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,641 | - |
$5,718
81,687
kWh
|
$1,923
-
kW-mo/yr
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,533 | $1,020 |
$1,895
27,079
kWh
|
$638
-
kW-mo/yr
|
- | |
03 | 2.7224: Reduce space conditioning during non-working hours | $2,473 | $2,950 |
$1,605
22,949
kWh
|
$588
-
kW-mo/yr
|
$280
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,444 | $1,640 |
$1,610
23,008
kWh
|
$834
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $2,062 | - |
$1,637
23,400
kWh
|
$425
-
kW-mo/yr
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,959 | $1,750 |
$1,466
20,939
kWh
|
$493
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $19,112 | $7,360 |
$13,931
199,062
kWh
|
$4,900
-
kW-mo/yr
|
$280
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs