| Assessment Year | 2023 |
|---|---|
| Principal Product | Packing Machinery Manufacturing |
| NAICS | 333993: Packaging Machinery Manufacturing |
| SIC | 3565: Packaging Machinery |
| Sales Range | $10 M to 50M |
| # of Employees | 110 |
| Plant Area |
121,563
ft2
|
| Annual Production | 350,000
lb
|
| Production Hrs. Annual | 4,056
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $37,262 | 749,000 |
kWh
|
$0.050 | |
| Electricity Demand | $35,428 | 2,586 |
kW-mo/yr
|
$13.70 | |
| Electricity Fees | $9,704 | - |
|
- | |
| Natural Gas | $42,137 | 6,657 |
MMBtu
|
$6.33 | |
| Waste Disposal Costs | |||||
| Water Usage | $12,600 | 585 |
Tgal
|
$21.53 | |
| TOTAL YEARLY COSTS | $137,131 | ||||
| RECOMMENDED SAVINGS* | $5,250 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $2,561 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,222 | $2,031 |
$1,448
28,960
kWh
|
$774
-
kW-mo/yr
|
- | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,952 | $4,375 |
$1,254
25,080
kWh
|
$698
-
kW-mo/yr
|
- | - | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $323 | $1,360 |
$323
6,450
kWh
|
- | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $286 | $500 |
$153
3,066
kWh
|
$58
-
kW-mo/yr
|
$75 | - | |
| 05 | 2.7444: Close holes and openings in building such as broken windows | $266 | $732 | - | - | - |
$266
-
MMBtu
|
|
| 06 | 2.7444: Close holes and openings in building such as broken windows | $201 | $380 | - | - | - |
$201
-
MMBtu
|
|
| TOTAL RECOMMENDED | $5,250 | $9,378 |
$3,178
63,556
kWh
|
$1,529
-
kW-mo/yr
|
$75 |
$468
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,561 | $6,235 |
$1,730
34,596
kWh
|
$755
-
kW-mo/yr
|
$75 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs