ITAC Assessment: WM0187
ITAC logo
ITAC Assessment: WM0187
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Industrial Dryers and Ovens for roll-to-roll processes
NAICS 333249: Other Industrial Machinery Manufacturing
SIC 3542: Machine Tools, Metal Forming Types
Sales Range $10
M
to 50
M
# of Employees 43
Plant Area 65,000
ft2
Annual Production 10
units
Production Hrs. Annual 3,150
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $10,425 204,411
kWh
Electricity Demand $11,528 1,104
kW-mo/yr
Electricity Fees $2,629 -
Natural Gas $14,545 2,258
MMBtu
Waste Disposal Costs
Water Usage $4,413 110
Tgal
Water Disposal $4,413 110
Tgal
TOTAL YEARLY COSTS $47,953
RECOMMENDED SAVINGS* $7,404 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,734

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,818 $3,500 $1,586
31,098
kWh
$1,232
-
kW-mo/yr
02 2.4314: Use synthetic lubricant $1,264 $2,400 $710
13,939
kWh
$554
-
kW-mo/yr
03 2.7135: Install occupancy sensors $1,137 $1,079 $624
12,242
kWh
$513
-
kW-mo/yr
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $984 $480 $553
10,836
kWh
$431
-
kW-mo/yr
05 2.7142: Utilize higher efficiency lamps and/or ballasts $668 $980 $374
7,340
kWh
$293
-
kW-mo/yr
06 2.4231: Reduce the pressure of compressed air to the minimum required $533 - $300
5,874
kWh
$234
-
kW-mo/yr
TOTAL RECOMMENDED $7,404 $8,439 $4,147
81,329
kWh
$3,257
-
kW-mo/yr
TOTAL IMPLEMENTED $5,734 $7,360 $3,223
63,213
kWh
$2,511
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs