Assessment Year | 2020 |
---|---|
Principal Product | Potable Drinking Water and Treat Wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | less than $500 k |
# of Employees | 12 |
Plant Area |
1,082,000
ft2
|
Annual Production | 15,000
Tgal
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $322,996 | 4,708,194 |
kWh
|
$0.069 |
Electricity Demand | $168,753 | 13,471 |
kW-mo/yr
|
$12.53 |
Electricity Fees | $27,165 | - |
|
- |
Natural Gas | $38,300 | 7,287 |
MMBtu
|
$5.26 |
TOTAL YEARLY COSTS | $557,214 | |||
RECOMMENDED SAVINGS* | $52,856 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,028 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $20,527 | $105,000 |
$20,527
276,867
kWh
|
- | - | |
02 | 2.4314: Use synthetic lubricant | $11,563 | $3,300 |
$11,563
168,554
kWh
|
- | - | |
03 | 2.6215: Shut off air conditioning in winter heating season | $9,593 | - | - | - |
$9,593
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,847 | $13,133 |
$4,215
61,448
kWh
|
$632
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,864 | $3,527 |
$1,864
27,174
kWh
|
- | - | |
06 | 2.7221: Lower temperature during the winter season and vice-versa | $1,164 | - |
$562
8,188
kWh
|
- |
$602
-
MMBtu
|
|
07 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $1,144 | $4,600 | - | - |
$1,144
-
MMBtu
|
|
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,058 | - |
$845
12,317
kWh
|
$213
-
kW-mo/yr
|
- | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $554 | $2,225 |
$493
7,176
kWh
|
$61
-
kW-mo/yr
|
- | |
10 | 2.4221: Install compressor air intakes in coolest locations | $542 | $1,785 |
$433
6,317
kWh
|
$109
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $52,856 | $133,570 |
$40,502
568,041
kWh
|
$1,015
-
kW-mo/yr
|
$11,339
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,028 | $3,527 |
$2,426
35,362
kWh
|
- |
$602
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs