Assessment Year 2019
Principal Product Vitreous plumbing fixtures
NAICS 327110: Pottery, Ceramics, and Plumbing Fixture Manufacturing
SIC 3261: Vitreous China Plumbing Fixtures and China and Earthenware Fittings and Bathroom Accessories
Sales Range $100
M
to 500
M
# of Employees 100
Plant Area 639,413
ft2
Annual Production 6,796,135
units
Production Hrs. Annual 7,056
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $434,169 5,642,996
kWh
Natural Gas $694,995 187,858
MMBtu
Waste Disposal Costs
Water Usage $9,968 6,070
Tgal
Water Disposal $18,101 5,243
Tgal
TOTAL YEARLY COSTS $1,157,233
RECOMMENDED SAVINGS* $71,222 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $42,169 $92,680 $42,169
548,077
kWh
-
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $10,023 $49,220 $10,023
130,276
kWh
-
03 2.4231: Reduce the pressure of compressed air to the minimum required $8,143 $8,425 $8,143
105,840
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,150 $2,000 $5,150
66,936
kWh
-
05 2.2414: Use waste heat from hot flue gases to preheat $3,217 $7,000 - $3,217
-
MMBtu
06 2.7423: Reduce heat gain by window tinting $1,426 $4,100 - $1,426
-
MMBtu
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,094 $2,750 $1,094
14,212
kWh
-
TOTAL RECOMMENDED $71,222 $166,175 $66,579
865,341
kWh
$4,643
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs