Assessment Year 2019
Principal Product Silica sand
NAICS 212322: Industrial Sand Mining
SIC 1446: Industrial Sand
Sales Range $1
M
to 5
M
# of Employees 114
Plant Area 26,136,000
ft2
Annual Production 2,700,000
units
Production Hrs. Annual 8,270
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,761,791 54,125,402
kWh
Electricity Fees $664,157 -
Natural Gas $2,181,438 524,674
MMBtu
TOTAL YEARLY COSTS $5,607,386
RECOMMENDED SAVINGS* $422,645 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $47,286

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2414: Use waste heat from hot flue gases to preheat $336,174 $82,000 - $336,174
-
MMBtu
02 2.7142: Utilize higher efficiency lamps and/or ballasts $31,481 $34,315 $31,481
616,803
kWh
-
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $25,347 $29,120 $25,347
496,715
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $9,430 $30,453 $9,430
184,788
kWh
-
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $9,068 $14,525 $9,068
177,698
kWh
-
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $6,375 $11,900 $6,375
124,931
kWh
-
07 2.7124: Make a practice of turning off lights when not needed $4,770 - $4,770
93,484
kWh
-
TOTAL RECOMMENDED $422,645 $202,313 $86,471
1,694,419
kWh
$336,174
-
MMBtu
TOTAL IMPLEMENTED $47,286 $76,668 $47,286
926,522
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs