Assessment Year 2017
Principal Product Treated Wastewater
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range $100
M
to 500
M
# of Employees 232
Plant Area 6,534,000
ft2
Annual Production 70,000,000,000
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $553,695 10,078,025
kWh
Electricity Demand $304,323 23,467
kW-mo/yr
Electricity Fees $10,546 -
Natural Gas $519,050 133,393
MMBtu
Waste Disposal Costs
Water Usage $129,459 34,004,198
Tgal
TOTAL YEARLY COSTS $1,517,073
RECOMMENDED SAVINGS* $107,498 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $86,995

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $47,713 $150,000 $16,081
292,704
kWh
$31,632
-
kW-mo/yr
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $16,077 $29,868 $9,710
176,476
kWh
$6,367
-
kW-mo/yr
03 2.7124: Make a practice of turning off lights when not needed $12,320 - $7,470
135,954
kWh
$4,850
-
kW-mo/yr
04 2.7135: Install occupancy sensors $10,947 $460 $8,805
121,112
kWh
$2,142
-
kW-mo/yr
05 2.7142: Utilize higher efficiency lamps and/or ballasts $8,535 $3,553 $5,176
94,218
kWh
$3,359
-
kW-mo/yr
06 2.7142: Utilize higher efficiency lamps and/or ballasts $7,480 $14,400 $7,480
117,892
kWh
-
07 2.7134: Use photocell controls $4,426 $1,430 $3,556
49,055
kWh
$870
-
kW-mo/yr
TOTAL RECOMMENDED $107,498 $199,711 $58,278
987,411
kWh
$49,220
-
kW-mo/yr
TOTAL IMPLEMENTED $86,995 $168,413 $45,012
761,880
kWh
$41,983
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs