Assessment Year | 2015 |
---|---|
Principal Product | Carbon Brushes |
NAICS | 335991: Carbon and Graphite Product Manufacturing |
SIC | 3624: Carbon and Graphite Products |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
90,000
ft2
|
Annual Production | 100,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $247,911 | 3,652,800 |
kWh
|
$0.068 |
Electricity Demand | $121,312 | 9,006 |
kW-mo/yr
|
$13.47 |
Electricity Fees | $2,973 | - |
|
- |
Natural Gas | $33,423 | 4,547 |
MMBtu
|
$7.35 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,970 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,526 | $12,300 |
$7,095
104,534
kWh
|
$431
-
kW-mo/yr
|
- | |
02 | 2.4314: Use synthetic lubricant | $8,412 | $2,365 |
$8,412
123,942
kWh
|
- | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,351 | $1,600 |
$3,351
49,380
kWh
|
- | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $2,974 | $150 |
$2,126
31,320
kWh
|
$849
-
kW-mo/yr
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,338 | $1,470 |
$1,674
24,662
kWh
|
$664
-
kW-mo/yr
|
- | |
06 | 2.2531: Re-size charging openings or add movable cover or door | $1,982 | $198 | - | - |
$1,982
-
MMBtu
|
|
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,542 | $320 |
$1,138
16,763
kWh
|
$404
-
kW-mo/yr
|
- | |
08 | 2.7111: Reduce illumination to minimum necessary levels | $624 | $2,210 |
$624
9,119
kWh
|
- | - | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $221 | $300 |
$221
3,256
kWh
|
- | - | |
TOTAL RECOMMENDED | $28,970 | $20,913 |
$24,640
362,976
kWh
|
$2,348
-
kW-mo/yr
|
$1,982
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs