ITAC Assessment: WM0079
ITAC logo
ITAC Assessment: WM0079
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2015
Principal Product Carbon Brushes
NAICS 335991: Carbon and Graphite Product Manufacturing
SIC 3624: Carbon and Graphite Products
Sales Range $10
M
to 50
M
# of Employees 95
Plant Area 90,000
ft2
Annual Production 100,000,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $247,911 3,652,800
kWh
Electricity Demand $121,312 9,006
kW-mo/yr
Electricity Fees $2,973 -
Natural Gas $33,423 4,547
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $28,970 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $7,526 $12,300 $7,095
104,534
kWh
$431
-
kW-mo/yr
-
02 2.4314: Use synthetic lubricant $8,412 $2,365 $8,412
123,942
kWh
- -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,351 $1,600 $3,351
49,380
kWh
- -
04 2.7111: Reduce illumination to minimum necessary levels $2,974 $150 $2,126
31,320
kWh
$849
-
kW-mo/yr
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,338 $1,470 $1,674
24,662
kWh
$664
-
kW-mo/yr
-
06 2.2531: Re-size charging openings or add movable cover or door $1,982 $198 - - $1,982
-
MMBtu
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,542 $320 $1,138
16,763
kWh
$404
-
kW-mo/yr
-
08 2.7111: Reduce illumination to minimum necessary levels $624 $2,210 $624
9,119
kWh
- -
09 2.6211: Conserve energy by efficient use of vending machines $221 $300 $221
3,256
kWh
- -
TOTAL RECOMMENDED $28,970 $20,913 $24,640
362,976
kWh
$2,348
-
kW-mo/yr
$1,982
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs