| Assessment Year | 2015 |
|---|---|
| Principal Product | Carbon Brushes |
| NAICS | 335991: Carbon and Graphite Product Manufacturing |
| SIC | 3624: Carbon and Graphite Products |
| Sales Range | $10 M to 50M |
| # of Employees | 95 |
| Plant Area |
90,000
ft2
|
| Annual Production | 100,000,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $247,911 | 3,652,800 |
kWh
|
$0.068 |
| Electricity Demand | $121,312 | 9,006 |
kW-mo/yr
|
$13.47 |
| Electricity Fees | $2,973 | - |
|
- |
| Natural Gas | $33,423 | 4,547 |
MMBtu
|
$7.35 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,970 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,526 | $12,300 |
$7,095
104,534
kWh
|
$431
-
kW-mo/yr
|
- | |
| 02 | 2.4314: Use synthetic lubricant | $8,412 | $2,365 |
$8,412
123,942
kWh
|
- | - | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,351 | $1,600 |
$3,351
49,380
kWh
|
- | - | |
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $2,974 | $150 |
$2,126
31,320
kWh
|
$849
-
kW-mo/yr
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,338 | $1,470 |
$1,674
24,662
kWh
|
$664
-
kW-mo/yr
|
- | |
| 06 | 2.2531: Re-size charging openings or add movable cover or door | $1,982 | $198 | - | - |
$1,982
-
MMBtu
|
|
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,542 | $320 |
$1,138
16,763
kWh
|
$404
-
kW-mo/yr
|
- | |
| 08 | 2.7111: Reduce illumination to minimum necessary levels | $624 | $2,210 |
$624
9,119
kWh
|
- | - | |
| 09 | 2.6211: Conserve energy by efficient use of vending machines | $221 | $300 |
$221
3,256
kWh
|
- | - | |
| TOTAL RECOMMENDED | $28,970 | $20,913 |
$24,640
362,976
kWh
|
$2,348
-
kW-mo/yr
|
$1,982
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs