Assessment Year 2014
Principal Product Aluminum Diecasting
NAICS 331523: Nonferrous Metal Die-Casting Foundries
SIC 3363: Aluminum Die-Castings
Sales Range $10
M
to 50
M
# of Employees 145
Plant Area 65,000
ft2
Annual Production 3,500
ton
Production Hrs. Annual 6,000
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $570,935 8,191,800
kWh
Electricity Demand $228,884 17,100
kW-mo/yr
Electricity Fees $(-25,701.0) -
Natural Gas $348,239 51,821
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $195,305 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,855

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings One-time Revenue or Avoided Cost Savings
01 2.2414: Use waste heat from hot flue gases to preheat $71,098 $51,000 - - $71,098
-
MMBtu
- -
02 2.2211: Use optimum temperature $55,730 - - - $55,730
-
MMBtu
- -
03 2.8114: Change rate schedules or other changes in utility service $44,848 $200,000 - - - - $44,848
04 2.4322: Use or replace with energy efficient substitutes $7,464 $602 $7,464
107,092
kWh
- - - -
05 2.7111: Reduce illumination to minimum necessary levels $6,689 $608 $5,115
73,382
kWh
$1,574
-
kW-mo/yr
- - -
06 2.4322: Use or replace with energy efficient substitutes $6,489 $9,750 $6,489
70,862
kWh
- - - -
07 2.2511: Insulate bare equipment $2,595 $2,500 $2,285
32,815
kWh
- - $310
-
Tgal
-
08 2.7135: Install occupancy sensors $391 $375 $391
5,616
kWh
- - - -
TOTAL RECOMMENDED $195,305 $264,835 $21,744
289,767
kWh
$1,574
-
kW-mo/yr
$126,828
-
MMBtu
$310
-
Tgal
$44,848
TOTAL IMPLEMENTED $7,855 $977 $7,855
112,708
kWh
- - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs