Assessment Year | 2014 |
---|---|
Principal Product | Plastic Parts |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 15 |
Plant Area |
20,000
ft2
|
Annual Production | 7,500,000
lb
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $74,342 | 1,227,679 |
kWh
|
$0.061 |
Electricity Demand | $31,870 | 4,249 |
kW-mo/yr
|
$7.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,031 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,185 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $266 | $132 |
$266
5,316
kWh
|
- | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $394 | $320 |
$302
5,080
kWh
|
$92
-
kW-mo/yr
|
- | |
03 | 4.424: Improve space comfort conditioning | $5,525 | $595 | - | - | $5,525 | |
04 | 4.652: Replace existing equipment with more suitable substitutes | $15,846 | $75,000 |
$13,016
214,921
kWh
|
$2,831
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $22,031 | $76,047 |
$13,584
225,317
kWh
|
$2,923
-
kW-mo/yr
|
$5,525 | ||
TOTAL IMPLEMENTED | $6,185 | $1,047 |
$568
10,396
kWh
|
$92
-
kW-mo/yr
|
$5,525 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs