| Assessment Year | 2012 |
|---|---|
| Principal Product | Scientific glassware |
| NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
| SIC | 3231: Glass Products, Made of Purchased Glass |
| Sales Range | $5 M to 10M |
| # of Employees | 30 |
| Plant Area |
44,000
ft2
|
| Annual Production | 5,181
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $65,578 | 988,800 |
kWh
|
$0.066 |
| Electricity Demand | $45,552 | 4,012 |
kW-mo/yr
|
$11.35 |
| Electricity Fees | $14,709 | - |
|
- |
| Natural Gas | $13,416 | 1,584 |
MMBtu
|
$8.47 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $19,216 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,577 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 3.4111: Use closed cycle process to minimize waste water production | $15,433 | $47,000 |
$(-12,889.0)
(-194,400)
kWh
|
$(-4,905.0)
-
kW-mo/yr
|
$8,783 |
$24,444
-
Tgal
|
|
| 02 | 2.7135: Install occupancy sensors | $233 | $630 |
$233
3,515
kWh
|
- | - | - | |
| 03 | 2.2511: Insulate bare equipment | $1,639 | $513 |
$1,639
24,730
kWh
|
- | - | - | |
| 04 | 4.463: Modify facility to avoid excess maintenance costs | $1,911 | $8,170 | - | - | $1,911 | - | |
| TOTAL RECOMMENDED | $19,216 | $56,313 |
$(-11,017.0)
(-166,155)
kWh
|
$(-4,905.0)
-
kW-mo/yr
|
$10,694 |
$24,444
-
Tgal
|
||
| TOTAL IMPLEMENTED | $17,577 | $55,800 |
$(-12,656.0)
(-190,885)
kWh
|
$(-4,905.0)
-
kW-mo/yr
|
$10,694 |
$24,444
-
Tgal
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs