Assessment Year 2012
Principal Product Sockets,pliers, extensions
NAICS 332216: Saw Blade and Handtool Manufacturing
SIC 3423: Hand and Edge Tools, Except Machine Tools and Handsaws
Sales Range $50
M
to 100
M
# of Employees 311
Plant Area 118,000
ft2
Annual Production 26,827,526
pieces
Production Hrs. Annual 7,200
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $674,395 11,672,049
kWh
Electricity Demand $236,619 21,744
kW-mo/yr
Electricity Fees $77,438 -
Natural Gas $284,499 34,795
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $79,059 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $41,950

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Other Liquid (non-haz) Savings
01 2.4314: Use synthetic lubricant $31,970 $25,000 $20,283
350,918
kWh
$11,687
-
kW-mo/yr
- - -
02 2.6212: Turn off equipment during breaks, reduce operating time $8,084 $360 $8,084
139,854
kWh
- - - -
03 2.7231: Use radiant heater for spot heating $327 $1,480 - - $327
-
MMBtu
- -
04 2.7491: Insulate glazing, walls, ceilings, and roofs $294 $368 - - $294
-
MMBtu
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,980 $1,125 $7,597
131,436
kWh
$2,383
-
kW-mo/yr
- - -
06 3.4153: Use counter current rinsing to reduce waste water $28,404 $14,713 - - - $17,042
-
Tgal
$11,362
-
gal
TOTAL RECOMMENDED $79,059 $43,046 $35,964
622,208
kWh
$14,070
-
kW-mo/yr
$621
-
MMBtu
$17,042
-
Tgal
$11,362
-
gal
TOTAL IMPLEMENTED $41,950 $26,125 $27,880
482,354
kWh
$14,070
-
kW-mo/yr
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Other Liquid (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs