Assessment Year | 2024 |
---|---|
Principal Product | internal combustion engines |
NAICS | 333618: Other Engine Equipment Manufacturing |
SIC | 3519: Internal Combustion Engines, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 869 |
Plant Area |
973,172
ft2
|
Annual Production | 979,021
pieces
|
Production Hrs. Annual | 5,912
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,621,332 | 30,995,286 |
kWh
|
$0.052 | |
Electricity Demand | $905,510 | 77,866 |
kW-mo/yr
|
$11.63 | |
Natural Gas | $642,932 | 122,461 |
MMBtu
|
$5.25 | |
Waste Disposal Costs | |||||
Water Usage | $115,467 | 14,627 |
Tgal
|
$7.89 | |
Water Disposal | $68,855 | 6,426 |
Tgal
|
$10.72 | |
TOTAL YEARLY COSTS | $3,354,096 | ||||
RECOMMENDED SAVINGS* | $525,351 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $1,633 | $6,555 |
$1,121
21,556
kWh
|
$512
-
kW-mo/yr
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,784 | $1,000 |
$3,981
76,559
kWh
|
$1,803
-
kW-mo/yr
|
- | - | - | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $13,797 | $4,800 | - | - |
$13,797
-
MMBtu
|
- | - | |
04 | 2.7135: Install occupancy sensors | $2,158 | $1,750 |
$2,158
41,504
kWh
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,374 | $117,036 |
$6,533
125,630
kWh
|
$3,489
-
kW-mo/yr
|
- | - | $10,352 | |
06 | 2.1122: Re-size charging openings or add a movable door on equipment | $45,827 | $6,720 | - | - |
$45,827
-
MMBtu
|
- | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $41,882 | $33,744 |
$41,882
805,430
kWh
|
- | - | - | - | |
08 | 3.4151: Minimize water usage | $71,580 | $385,388 | - | - | - |
$71,580
-
Tgal
|
- | |
09 | 2.9114: Use solar heat to make electricty | $322,316 | $3,602,500 |
$322,316
6,198,386
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $525,351 | $4,159,493 |
$377,991
7,269,065
kWh
|
$5,804
-
kW-mo/yr
|
$59,624
-
MMBtu
|
$71,580
-
Tgal
|
$10,352 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs