| Assessment Year | 2012 |
|---|---|
| Principal Product | Industrial Radiators |
| NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 190 |
| Plant Area |
175,000
ft2
|
| Annual Production | 20,000
pieces
|
| Production Hrs. Annual | 3,000
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $119,491 | 1,659,600 |
kWh
|
$0.072 |
| Electricity Demand | $86,653 | 7,632 |
kW-mo/yr
|
$11.35 |
| Electricity Fees | $54,563 | - |
|
- |
| Natural Gas | $58,676 | 6,130 |
MMBtu
|
$9.57 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $126,184 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $55,728 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3137: Use power during off-peak periods | $56,454 | - | - |
$47,711
-
kW-mo/yr
|
$8,743 | - | - | |
| 02 | 2.7134: Use photocell controls | $875 | $750 |
$875
13,172
kWh
|
- | - | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $52,844 | $55,770 |
$36,265
506,189
kWh
|
$16,579
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $243 | $30 |
$243
3,475
kWh
|
- | - | - | - | |
| 05 | 2.2511: Insulate bare equipment | $1,425 | $500 | - | - | - |
$1,425
-
MMBtu
|
- | |
| 06 | 2.4224: Upgrade controls on compressors | $11,459 | - |
$11,459
159,952
kWh
|
- | - | - | - | |
| 07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,884 | - | - | - | - | - |
$2,884
-
lb
|
|
| TOTAL RECOMMENDED | $126,184 | $57,050 |
$48,842
682,788
kWh
|
$64,290
-
kW-mo/yr
|
$8,743 |
$1,425
-
MMBtu
|
$2,884
-
lb
|
||
| TOTAL IMPLEMENTED | $55,728 | $55,770 |
$36,265
506,189
kWh
|
$16,579
-
kW-mo/yr
|
- | - |
$2,884
-
lb
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs