Assessment Year | 2005 |
---|---|
Principal Product | Paper Napkins and Plates |
NAICS | 322299: All Other Converted Paper Product Manufacturing |
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | less than $500 k |
# of Employees | 120 |
Plant Area |
300,000
ft2
|
Annual Production | 7,800
ton
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $147,165 | 5,360,135 |
kWh
|
$0.027 |
Electricity Demand | $112,375 | 12,771 |
kW-mo/yr
|
$8.80 |
Electricity Fees | $62,286 | - |
|
- |
Natural Gas | $38,732 | 46,580 |
MMBtu
|
$0.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $166,407 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $51,992 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.132: Purchase new equipment to reduce material use / cost | $72,000 | $85,000 | - | - | - | $72,000 | |
02 | 2.4239: Eliminate or reduce compressed air usage | $42,415 | $4,000 |
$21,537
745,174
kWh
|
$20,878
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $33,445 | $86,400 |
$20,392
705,600
kWh
|
$13,053
-
kW-mo/yr
|
- | - | |
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $12,421 | - | - |
$12,421
-
kW-mo/yr
|
- | - | |
05 | 2.6218: Turn off equipment when not in use | $4,656 | $500 | - | - |
$4,656
-
MMBtu
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,470 | $60 |
$1,470
50,868
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $166,407 | $175,960 |
$43,399
1,501,642
kWh
|
$46,352
-
kW-mo/yr
|
$4,656
-
MMBtu
|
$72,000 | ||
TOTAL IMPLEMENTED | $51,992 | $86,960 |
$21,862
756,468
kWh
|
$25,474
-
kW-mo/yr
|
$4,656
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs