Assessment Year 2003
Principal Product Shylight Frames
NAICS 332322: Sheet Metal Work Manufacturing
SIC 3422:
Sales Range $10
M
to 50
M
# of Employees 86
Plant Area 86,000
ft2
Annual Production 0
units
Production Hrs. Annual 2,675
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $29,943 913,680
kWh
Electricity Demand $28,794 2,767
kW-mo/yr
Electricity Fees $6,831 -
Natural Gas $25,731 4,519
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $6,577 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
01 2.8121: Apply for tax-free status for energy purchases $3,066 - - - - - $3,066
02 2.1133: Adjust burners for efficient operation $1,887 $500 - - $1,887
-
MMBtu
- -
03 2.3132: Recharge batteries on during off-peak demand periods $700 $100 - $672
-
kW-mo/yr
- $28 -
04 2.7135: Install occupancy sensors $617 $2,400 $259
7,123
kWh
$358
-
kW-mo/yr
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $185 $102 $91
2,494
kWh
$94
-
kW-mo/yr
- - -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $122 - $44
1,279
kWh
$78
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $6,577 $3,102 $394
10,896
kWh
$1,202
-
kW-mo/yr
$1,887
-
MMBtu
$28 $3,066
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs