Assessment Year | 2002 |
---|---|
Principal Product | Recondition Containers |
NAICS |
n/a
|
SIC | 2449: Wood Containers, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 82 |
Plant Area |
125,000
ft2
|
Annual Production | 2,600,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $52,030 | 1,719,298 |
kWh
|
$0.030 |
Electricity Demand | $30,783 | 5,923 |
kW-mo/yr
|
$5.20 |
Electricity Fees | $6,826 | - |
|
- |
Natural Gas | $212,455 | 36,351 |
MMBtu
|
$5.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $48,131 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,148 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.3132: Use reverse osmosis to concentrate material | $14,059 | $20,000 | - | - | - |
$15,359
-
Tgal
|
$(-1,300.0) | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $10,458 | $500 | - | - |
$10,458
-
MMBtu
|
- | - | |
03 | 3.3131: Use evaporation to concentrate material | $9,308 | $11,000 | - | - |
$(-1,022.0)
-
MMBtu
|
$9,000
-
Tgal
|
$1,330 | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $6,599 | $12,000 | - | - |
$6,599
-
MMBtu
|
- | - | |
05 | 2.2514: Cover open tanks | $3,017 | $864 | - | - |
$3,017
-
MMBtu
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,966 | $5,584 |
$2,358
73,920
kWh
|
$608
-
kW-mo/yr
|
- | - | - | |
07 | 2.7135: Install occupancy sensors | $1,365 | $2,500 |
$960
30,091
kWh
|
$405
-
kW-mo/yr
|
- | - | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $359 | $369 |
$286
8,952
kWh
|
$73
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $48,131 | $52,817 |
$3,604
112,963
kWh
|
$1,086
-
kW-mo/yr
|
$19,052
-
MMBtu
|
$24,359
-
Tgal
|
$30 | ||
TOTAL IMPLEMENTED | $15,148 | $8,953 |
$3,604
112,963
kWh
|
$1,086
-
kW-mo/yr
|
$10,458
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs