Assessment Year | 2002 |
---|---|
Principal Product | Plastic Components |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
38,000
ft2
|
Annual Production | 1,700,000
lb
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $34,296 | 1,135,361 |
kWh
|
$0.030 |
Electricity Demand | $34,980 | 4,595 |
kW-mo/yr
|
$7.61 |
Electricity Fees | $21,083 | - |
|
- |
Natural Gas | $28,950 | 8,206 |
MMBtu
|
$3.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,392 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,709 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $2,499 | $1,000 | - | - |
$2,499
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,839 | $5,926 |
$1,174
36,816
kWh
|
$665
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,475 | $60 |
$941
29,489
kWh
|
$534
-
kW-mo/yr
|
- | - | |
04 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $683 | $500 | - | - | - |
$683
-
lb
|
|
05 | 2.2136: Install / repair insulation on steam lines | $424 | $39 | - | - |
$424
-
MMBtu
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $173 | - |
$108
3,370
kWh
|
$65
-
kW-mo/yr
|
- | - | |
07 | 2.7135: Install occupancy sensors | $299 | $700 |
$230
7,200
kWh
|
$69
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $7,392 | $8,225 |
$2,453
76,875
kWh
|
$1,333
-
kW-mo/yr
|
$2,923
-
MMBtu
|
$683
-
lb
|
||
TOTAL IMPLEMENTED | $6,709 | $7,725 |
$2,453
76,875
kWh
|
$1,333
-
kW-mo/yr
|
$2,923
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs