| Assessment Year | 1982 |
|---|---|
| Principal Product | LEAD |
| NAICS |
n/a
|
| SIC | 3341: Secondary Smelting and Refining of Nonferrous Metals |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
n/a
|
| Annual Production | 25,900
ton
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $117,845 | 2,834,994 |
kWh
|
$0.042 |
| Natural Gas | $229,246 | 57,282 |
MMBtu
|
$4.00 |
| Fuel Oil #2 | $1,401 | 196 |
MMBtu
|
$7.15 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $84,023 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $23,148 | $15,500 | - |
$23,148
-
MMBtu
|
|
| 02 | 2.2514: Cover open tanks | $55,090 | $5,750 | - |
$55,090
-
MMBtu
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $2,398 | - |
$2,398
57,151
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,387 | $872 |
$3,387
80,598
kWh
|
- | |
| TOTAL RECOMMENDED | $84,023 | $22,122 |
$5,785
137,749
kWh
|
$78,238
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs