Assessment Year | 2002 |
---|---|
Principal Product | Brass Casting |
NAICS |
n/a
|
SIC | 3369: Nonferrous Foundries, Except Aluminum and Copper |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
67,000
ft2
|
Annual Production | 1,700,000
lb
|
Production Hrs. Annual | 4,200
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $169,604 | 6,517,639 |
kWh
|
$0.026 |
Electricity Demand | $117,723 | 13,726 |
kW-mo/yr
|
$8.58 |
Electricity Fees | $31,783 | - |
|
- |
Natural Gas | $97,673 | 21,342 |
MMBtu
|
$4.58 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,876 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,155 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 3.3131: Use evaporation to concentrate material | $13,072 | $12,500 | - | - |
$(-42.0)
-
MMBtu
|
$13,114
-
Tgal
|
- | - | |
02 | 2.2437: Recover waste heat from equipment | $3,596 | $1,000 | - | - |
$3,596
-
MMBtu
|
- | - | - | |
03 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $3,296 | - | - | - | - | - |
$3,296
-
lb
|
- | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,616 | - |
$2,222
77,140
kWh
|
$3,649
-
kW-mo/yr
|
$(-3,505.0)
-
MMBtu
|
- | - | $(-750.0) | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,252 | $1,086 |
$766
27,851
kWh
|
$486
-
kW-mo/yr
|
- | - | - | - | |
06 | 3.7137: Replace cloth rags with paper towels | $737 | - | - | - | - | - |
$737
-
lb
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $307 | $68 |
$196
7,140
kWh
|
$111
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $23,876 | $14,654 |
$3,184
112,131
kWh
|
$4,246
-
kW-mo/yr
|
$49
-
MMBtu
|
$13,114
-
Tgal
|
$4,033
-
lb
|
$(-750.0) | ||
TOTAL IMPLEMENTED | $5,155 | $2,154 |
$962
34,991
kWh
|
$597
-
kW-mo/yr
|
$3,596
-
MMBtu
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |