ITAC Assessment: KU0296
ITAC logo
ITAC Assessment: KU0296
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1989
Principal Product AUTOMOTIVE RADIATORS
NAICS
n/a
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $10
M
to 50
M
# of Employees 260
Plant Area
n/a
Annual Production 700,000
pieces
Production Hrs. Annual 3,808
hrs
Location (State) Kansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $227,961 5,281,946
kWh
Natural Gas $185,671 59,749
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $9,509 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,509

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2443: Re-use or recycle hot or cold process exhaust air $5,891 $15,450 $(-329.0)
(-7,620)
kWh
$6,220
-
MMBtu
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,025 $1,690 $1,025
23,740
kWh
-
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $620 - $620
14,361
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,973 $5,262 $1,973
45,721
kWh
-
TOTAL RECOMMENDED $9,509 $22,402 $3,289
76,202
kWh
$6,220
-
MMBtu
TOTAL IMPLEMENTED $9,509 $22,402 $3,289
76,202
kWh
$6,220
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs