ITAC Assessment: WI0397
ITAC logo
ITAC Assessment: WI0397
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2001
Principal Product Food Service Equipment
NAICS
n/a
SIC 3589: Service Industry Machinery, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 290
Plant Area 212,000
ft2
Annual Production 100,000
pieces
Production Hrs. Annual 6,075
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $111,586 3,624,471
kWh
Electricity Demand $55,405 10,407
kW-mo/yr
Electricity Fees $18,972 -
Natural Gas $45,257 8,962
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $21,394 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $10,138

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings Solid Waste (non-haz) Savings Personnel Changes Savings Primary Raw Material Savings
01 3.6193: Install equipment (eg compactor) to reduce disposal costs $8,173 - - - - - $8,173
-
lb
- -
02 3.8142: Distill contaminated solvents for reuse $3,674 $7,700 - - - $4,756
-
gal
$(-288.0)
-
lb
$(-481.0) $(-313.0)
03 3.3131: Use evaporation to concentrate material $3,585 $10,000 - - $(-104.0)
-
MMBtu
$4,289
-
gal
- $(-600.0) -
04 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $2,972 $6,675 $2,972
92,022
kWh
- - - - - -
05 2.7135: Install occupancy sensors $1,025 $2,400 $427
13,222
kWh
$598
-
kW-mo/yr
- - - - -
06 2.6218: Turn off equipment when not in use $813 - $813
25,178
kWh
- - - - - -
07 2.4221: Install compressor air intakes in coolest locations $650 $640 $523
16,186
kWh
$127
-
kW-mo/yr
- - - - -
08 2.3134: Shift from daytime to nighttime operation $502 - - $502
-
kW-mo/yr
- - - - -
TOTAL RECOMMENDED $21,394 $27,415 $4,735
146,608
kWh
$1,227
-
kW-mo/yr
$(-104.0)
-
MMBtu
$9,045
-
gal
$7,885
-
lb
$(-1,081.0) $(-313.0)
TOTAL IMPLEMENTED $10,138 $640 $1,336
41,364
kWh
$629
-
kW-mo/yr
- - $8,173
-
lb
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings Solid Waste (non-haz) Savings Personnel Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs