Assessment Year | 1998 |
---|---|
Principal Product | Steel Rolls |
NAICS |
n/a
|
SIC | 3547: Rolling Mill Machinery and Equipment |
Sales Range | $1 M to 5M |
# of Employees | 32 |
Plant Area |
30,000
ft2
|
Annual Production | 600
pieces
|
Production Hrs. Annual | 5,125
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,340 | 798,359 |
kWh
|
$0.038 |
Electricity Demand | $28,627 | 2,389 |
kW-mo/yr
|
$11.98 |
Electricity Fees | $1,308 | - |
|
- |
Natural Gas | $121,397 | 34,047 |
MMBtu
|
$3.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $174,347 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,658 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.431: Train operators for maximum operating efficiency | $153,750 | $30,000 | - | - | - | - | - | $153,750 | - | |
02 | 2.1221: Replace obsolete burners with more efficient ones | $12,702 | $42,000 | - | - |
$12,702
-
MMBtu
|
- | - | - | - | |
03 | 3.3122: Use filtration, centrifuging to remove contaminants | $2,744 | $7,000 | - | - | - | - | - | - | $2,744 | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,170 | - |
$1,179
29,601
kWh
|
$991
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.7144: Install spectral reflectors / delamp | $1,422 | - |
$968
24,326
kWh
|
$454
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 3.8142: Distill contaminated solvents for reuse | $1,071 | $4,000 | - | - | - |
$1,937
-
gal
|
$(-124.0)
-
lb
|
$(-560.0) | $(-182.0) | |
07 | 3.8121: Cover containers to minimize evaporative losses | $488 | - | - | - | - | - | - | - | $488 | |
TOTAL RECOMMENDED | $174,347 | $83,000 |
$2,147
53,927
kWh
|
$1,445
-
kW-mo/yr
|
$12,702
-
MMBtu
|
$1,937
-
gal
|
$(-124.0)
-
lb
|
$153,190 | $3,050 | ||
TOTAL IMPLEMENTED | $2,658 | - |
$1,179
29,601
kWh
|
$991
-
kW-mo/yr
|
- | - | - | - | $488 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs