ITAC Assessment: WI0267
ITAC logo
ITAC Assessment: WI0267
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Dispossable dinnerware
NAICS
n/a
SIC 2656: Sanitary Food Containers, Except Folding
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area 188,000
ft2
Annual Production 27,500,000
lb
Production Hrs. Annual 8,736
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $813,384 23,723,623
kWh
Electricity Demand $471,614 37,969
kW-mo/yr
Electricity Fees $(-20,554.0) -
Natural Gas $100,314 28,068
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $98,834 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings Solid Waste (non-haz) Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $27,762 $8,906 n/a $16,690
463,365
kWh
$11,072
-
kW-mo/yr
- - -
02 2.4314: Use synthetic lubricant $16,841 - n/a $6,335
175,850
kWh
$10,506
-
kW-mo/yr
- - -
03 2.1311: Replace electrically-operated equipment with fossil fuel equipment $14,729 $45,000 n/a $30,154
837,632
kWh
$17,977
-
kW-mo/yr
$(-33,402.0)
-
MMBtu
- -
04 2.2621: Modify refrigeration system to operate at a lower pressure $13,635 $39,000 n/a $4,246
117,819
kWh
$9,389
-
kW-mo/yr
- - -
05 2.7243: Improve air circulation with destratification fans / other methods $9,054 $16,740 n/a $1,189
33,118
kWh
- $7,865
-
MMBtu
- -
06 3.6192: Use a less expensive method of waste removal $6,670 - n/a - - - - $6,670
-
lb
07 2.3135: Schedule routine maintenance during non-operating periods $4,867 - n/a - $4,867
-
kW-mo/yr
- - -
08 3.6192: Use a less expensive method of waste removal $3,040 - n/a - - - $3,040
-
gal
-
09 2.3132: Recharge batteries on during off-peak demand periods $2,236 $5,000 n/a - $2,236
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $98,834 $114,646 $58,614
1,627,784
kWh
$56,047
-
kW-mo/yr
$(-25,537.0)
-
MMBtu
$3,040
-
gal
$6,670
-
lb
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs