| Assessment Year | 1996 |
|---|---|
| Principal Product | Dispossable dinnerware |
| NAICS |
n/a
|
| SIC | 2656: Sanitary Food Containers, Except Folding |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
188,000
ft2
|
| Annual Production | 27,500,000
lb
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $813,384 | 23,723,623 |
kWh
|
$0.034 |
| Electricity Demand | $471,614 | 37,969 |
kW-mo/yr
|
$12.42 |
| Electricity Fees | $(-20,554.0) | - |
|
- |
| Natural Gas | $100,314 | 28,068 |
MMBtu
|
$3.57 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $98,834 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $27,762 | $8,906 | n/a |
$16,690
463,365
kWh
|
$11,072
-
kW-mo/yr
|
- | - | - |
| 02 | 2.4314: Use synthetic lubricant | $16,841 | - | n/a |
$6,335
175,850
kWh
|
$10,506
-
kW-mo/yr
|
- | - | - |
| 03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $14,729 | $45,000 | n/a |
$30,154
837,632
kWh
|
$17,977
-
kW-mo/yr
|
$(-33,402.0)
-
MMBtu
|
- | - |
| 04 | 2.2621: Modify refrigeration system to operate at a lower pressure | $13,635 | $39,000 | n/a |
$4,246
117,819
kWh
|
$9,389
-
kW-mo/yr
|
- | - | - |
| 05 | 2.7243: Improve air circulation with destratification fans / other methods | $9,054 | $16,740 | n/a |
$1,189
33,118
kWh
|
- |
$7,865
-
MMBtu
|
- | - |
| 06 | 3.6192: Use a less expensive method of waste removal | $6,670 | - | n/a | - | - | - | - |
$6,670
-
lb
|
| 07 | 2.3135: Schedule routine maintenance during non-operating periods | $4,867 | - | n/a | - |
$4,867
-
kW-mo/yr
|
- | - | - |
| 08 | 3.6192: Use a less expensive method of waste removal | $3,040 | - | n/a | - | - | - |
$3,040
-
gal
|
- |
| 09 | 2.3132: Recharge batteries on during off-peak demand periods | $2,236 | $5,000 | n/a | - |
$2,236
-
kW-mo/yr
|
- | - | - |
| TOTAL RECOMMENDED | $98,834 | $114,646 |
$58,614
1,627,784
kWh
|
$56,047
-
kW-mo/yr
|
$(-25,537.0)
-
MMBtu
|
$3,040
-
gal
|
$6,670
-
lb
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs