Assessment Year 1995
Principal Product Forgings (hand tools)
NAICS
n/a
SIC 3423: Hand and Edge Tools, Except Machine Tools and Handsaws
Sales Range $5
M
to 10
M
# of Employees 49
Plant Area 115,000
ft2
Annual Production 1,100
ton
Production Hrs. Annual 2,100
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $111,051 1,282,532
kWh
Natural Gas $127,495 49,968
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $11,606 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,981

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Water Disposal Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,254 $270 $3,254
37,515
kWh
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $891 $3,960 $891
10,258
kWh
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $470 $909 $470
5,569
kWh
- -
04 2.2515: Use optimum thickness insulation $1,323 $1,461 - $1,323
-
MMBtu
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $764 - $764
8,792
kWh
- -
06 2.3132: Recharge batteries on during off-peak demand periods $404 - $404
-
kWh
- -
07 3.4114: Replace city water with recycled water via cooling tower $4,500 $7,000 - - $4,500
-
Tgal
TOTAL RECOMMENDED $11,606 $13,600 $5,783
62,134
kWh
$1,323
-
MMBtu
$4,500
-
Tgal
TOTAL IMPLEMENTED $4,981 $1,731 $3,658
37,515
kWh
$1,323
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs