| Assessment Year | 1995 |
|---|---|
| Principal Product | Shopping Carts |
| NAICS |
n/a
|
| SIC | 3496: Miscellaneous Fabricated Wire Products |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
137,000
ft2
|
| Annual Production | 170,000
pieces
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $231,688 | 2,648,886 |
kWh
|
$0.087 |
| Natural Gas | $98,945 | 34,083 |
MMBtu
|
$2.90 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $95,589 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3312: Install efficient rectifiers | $68,726 | $81,000 |
$68,726
785,756
kWh
|
- | |
| 02 | 2.7221: Lower temperature during the winter season and vice-versa | $13,411 | $2,500 | - |
$13,411
-
MMBtu
|
|
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $4,134 | $1,400 | - |
$4,134
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,493 | $6,600 |
$4,493
51,290
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $384 | $880 |
$384
4,396
kWh
|
- | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,441 | $180 |
$4,441
48,652
kWh
|
- | |
| TOTAL RECOMMENDED | $95,589 | $92,560 |
$78,044
890,094
kWh
|
$17,545
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs