Assessment Year | 1991 |
---|---|
Principal Product | ICE CREAM CONES |
NAICS |
n/a
|
SIC | 2052: Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 360,000,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $60,108 | 1,265,533 |
kWh
|
$0.047 |
Natural Gas | $138,387 | 38,594 |
MMBtu
|
$3.59 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,148 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,148 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $15,437 | - |
$3,432
-
kWh
|
$12,005
-
MMBtu
|
|
02 | 2.2437: Recover waste heat from equipment | $2,500 | $10,000 | - |
$2,500
-
MMBtu
|
|
03 | 2.2511: Insulate bare equipment | $261 | $188 | - |
$261
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $587 | $240 |
$587
12,309
kWh
|
- | |
05 | 2.7226: Use computer programs to optimize hvac performance | $313 | $2,100 |
$313
6,741
kWh
|
- | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $370 | $1,400 |
$546
11,430
kWh
|
$(-176.0)
-
MMBtu
|
|
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $200 | - |
$200
4,103
kWh
|
- | |
08 | 2.6232: Install set-back timers | $186 | $200 |
$186
3,810
kWh
|
- | |
09 | 2.7221: Lower temperature during the winter season and vice-versa | $160 | $200 | - |
$160
-
MMBtu
|
|
10 | 2.6214: Shut off pilots in standby equipment | $134 | - | - |
$134
-
MMBtu
|
|
TOTAL RECOMMENDED | $20,148 | $14,328 |
$5,264
38,393
kWh
|
$14,884
-
MMBtu
|
||
TOTAL IMPLEMENTED | $20,148 | $14,328 |
$5,264
38,393
kWh
|
$14,884
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs