Assessment Year | 1987 |
---|---|
Principal Product | SPECIALTY HAND TOOLS |
NAICS |
n/a
|
SIC | 3423: Hand and Edge Tools, Except Machine Tools and Handsaws |
Sales Range | $10 M to 50M |
# of Employees | 170 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,125
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $95,349 | 1,433,763 |
kWh
|
$0.067 |
Natural Gas | $8,263 | 1,658 |
MMBtu
|
$4.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,255 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,936 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4312: Improve lubrication practices | $5,838 | - |
$5,838
87,925
kWh
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,114 | - |
$1,114
16,706
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $474 | $110 |
$474
7,034
kWh
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $466 | $620 |
$466
7,034
kWh
|
- | - | |
05 | 2.3191: Use demand controller or load shedder | $2,319 | $2,700 |
$2,319
-
kWh
|
- | - | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $44 | - | - |
$384
-
MMBtu
|
$(-340.0) | |
TOTAL RECOMMENDED | $10,255 | $3,430 |
$10,211
118,699
kWh
|
$384
-
MMBtu
|
$(-340.0) | ||
TOTAL IMPLEMENTED | $7,936 | $730 |
$7,892
118,699
kWh
|
$384
-
MMBtu
|
$(-340.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs