Assessment Year | 2023 |
---|---|
Principal Product | Precision sheet metal manufacturing, stamping and fabrication |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 48 |
Plant Area |
30,000
ft2
|
Annual Production | 40,000
lb
|
Production Hrs. Annual | 4,940
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $115,724 | 963,360 |
kWh
|
$0.12 |
TOTAL YEARLY COSTS | $115,724 | |||
RECOMMENDED SAVINGS* | $958,225 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $879,050 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Increase in Production Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,807 | $2,080 |
$1,807
15,047
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,660 | - |
$1,660
13,820
kWh
|
- | |
03 | 2.7135: Install occupancy sensors | $557 | $1,253 |
$557
4,649
kWh
|
- | |
04 | 2.9114: Use solar heat to make electricty | $75,708 | $310,796 |
$75,708
630,371
kWh
|
- | |
05 | 2.4321: Upgrade obsolete equipment | $878,493 | $1,900,000 |
$4,493
37,440
kWh
|
$874,000 | |
TOTAL RECOMMENDED | $958,225 | $2,214,129 |
$84,225
701,327
kWh
|
$874,000 | ||
TOTAL IMPLEMENTED | $879,050 | $1,901,253 |
$5,050
42,089
kWh
|
$874,000 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs