| Assessment Year | 2022 |
|---|---|
| Principal Product | Paper (except Newsprint) Mills. |
| NAICS | 322121: Paper (except Newsprint) Mills |
| SIC | 2621: Paper Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 106 |
| Plant Area |
50,000
ft2
|
| Annual Production | 8,125
ton
|
| Production Hrs. Annual | 5,200
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $57,931 | 790,974 |
kWh
|
$0.073 |
| Electricity Demand | $15,525 | 2,535 |
kW-mo/yr
|
$6.12 |
| Electricity Fees | $12,992 | - |
|
- |
| Natural Gas | $9,695 | 797 |
MMBtu
|
$12.16 |
| Fuel Oil #1 | $10,958 | 1,499 |
MMBtu
|
$7.31 |
| TOTAL YEARLY COSTS | $107,101 | |||
| RECOMMENDED SAVINGS* | $10,612 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,612 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $3,539 | $5,669 |
$3,539
48,344
kWh
|
- | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $2,053 | $286 |
$1,721
23,510
kWh
|
$332
-
kW-mo/yr
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,126 | $6,616 |
$2,097
28,654
kWh
|
$28
-
kW-mo/yr
|
- | |
| 04 | 2.7224: Reduce space conditioning during non-working hours | $708 | $760 | - | - |
$708
-
MMBtu
|
|
| 05 | 2.7135: Install occupancy sensors | $2,186 | $1,771 |
$2,157
29,473
kWh
|
$29
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $10,612 | $15,102 |
$9,515
129,981
kWh
|
$389
-
kW-mo/yr
|
$708
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $10,612 | $15,102 |
$9,515
129,981
kWh
|
$389
-
kW-mo/yr
|
$708
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs