Assessment Year | 2022 |
---|---|
Principal Product | manufacturing sheet metal work for buildings, airports, vehicles, etc |
NAICS | 332322: Sheet Metal Work Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $100 M to 500M |
# of Employees | 75 |
Plant Area |
50,000
ft2
|
Annual Production | 100,000
units
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $158,295 | 1,942,271 |
kWh
|
$0.082 |
Electricity Demand | $20,882 | 5,008 |
kW-mo/yr
|
$4.17 |
Electricity Fees | $13,003 | - |
|
- |
Natural Gas | $62,694 | 5,887 |
MMBtu
|
$10.65 |
TOTAL YEARLY COSTS | $254,874 | |||
RECOMMENDED SAVINGS* | $4,255 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,255 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,861 | $2,080 |
$1,634
20,050
kWh
|
$227
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $1,799 | $2,329 |
$1,799
22,073
kWh
|
- | - | |
03 | 2.7224: Reduce space conditioning during non-working hours | $595 | - | - | - |
$595
-
MMBtu
|
|
TOTAL RECOMMENDED | $4,255 | $4,409 |
$3,433
42,123
kWh
|
$227
-
kW-mo/yr
|
$595
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,255 | $4,409 |
$3,433
42,123
kWh
|
$227
-
kW-mo/yr
|
$595
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs