Assessment Year | 2022 |
---|---|
Principal Product | Roasted Coffe, Single Serve Coffee, Bagged Coffee |
NAICS | 311920: Coffee and Tea Manufacturing |
SIC | 2095: Roasted Coffee |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
43,800
ft2
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $37,365 | 376,300 |
kWh
|
$0.099 | |
Electricity Demand | $14,357 | 1,419 |
kW-mo/yr
|
$10.12 | |
Electricity Fees | $5,079 | - |
|
- | |
Natural Gas | $77,103 | 7,322 |
MMBtu
|
$10.53 | |
Waste Disposal Costs | |||||
Solid Waste (non-haz) | $36,658 | 259,100 |
lb
|
$0.14 | |
TOTAL YEARLY COSTS | $170,562 | ||||
RECOMMENDED SAVINGS* | $14,768 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $11,028 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,907 | $2,080 |
$4,565
45,968
kWh
|
$1,342
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,845 | $6,616 |
$2,845
28,654
kWh
|
- | - | |
03 | 2.7135: Install occupancy sensors | $2,927 | $1,771 |
$2,927
29,473
kWh
|
- | - | |
04 | 2.7224: Reduce space conditioning during non-working hours | $2,276 | - | - | - |
$2,276
-
MMBtu
|
|
05 | 2.4133: Use most efficient type of electric motors | $814 | $3,411 |
$814
8,193
kWh
|
- | - | |
TOTAL RECOMMENDED | $14,768 | $13,878 |
$11,150
112,288
kWh
|
$1,342
-
kW-mo/yr
|
$2,276
-
MMBtu
|
||
TOTAL IMPLEMENTED | $11,028 | $8,696 |
$7,410
74,622
kWh
|
$1,342
-
kW-mo/yr
|
$2,276
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs