| Assessment Year | 2010 |
|---|---|
| Principal Product | Corrugated Paper |
| NAICS | 322299: All Other Converted Paper Product Manufacturing |
| SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 275 |
| Plant Area |
40,000
ft2
|
| Annual Production | 50,000
ton
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $38,790,795 | 1,020,810,394 |
kWh
|
$0.038 |
| Natural Gas | $15,490,169 | 2,065,355 |
MMBtu
|
$7.50 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $1,075,876 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,059,399 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $977,184 | $420,000 | - | - |
$977,184
-
MMBtu
|
- | |
| 02 | 2.1232: Keep boiler tubes clean | $82,215 | $50,000 | - | - | - |
$82,215
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,477 | $32,020 |
$14,424
379,597
kWh
|
$2,053
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $1,075,876 | $502,020 |
$14,424
379,597
kWh
|
$2,053
-
kW-mo/yr
|
$977,184
-
MMBtu
|
$82,215
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,059,399 | $470,000 | - | - |
$977,184
-
MMBtu
|
$82,215
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs