Assessment Year 2009
Principal Product Pulp and Paper Products
NAICS 322110: Pulp Mills
SIC 2611: Pulp Mills
Sales Range greater than $500
M
# of Employees 350
Plant Area 250,000
ft2
Annual Production 800,000
ton
Production Hrs. Annual 7,358
hrs
Location (State) Washington

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $3,440,976 38,457,000
kWh
Electricity Demand $342,040 204,000
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $324,407 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Fuel Oil #6 Savings
01 2.4133: Use most efficient type of electric motors $134,729 $705,718 $124,234
4,141,132
kWh
$10,495
-
kW-mo/yr
-
02 2.1232: Keep boiler tubes clean $115,460 $50,000 - - $115,460
-
MMBtu
03 2.3212: Optimize plant power factor $74,218 $166,366 $71,728
1,769,000
kWh
$2,490
-
kW-mo/yr
-
TOTAL RECOMMENDED $324,407 $922,084 $195,962
5,910,132
kWh
$12,985
-
kW-mo/yr
$115,460
-
MMBtu
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs