| Assessment Year | 2008 |
|---|---|
| Principal Product | Plastic and Cardboard Packaging |
| NAICS | 322212: Folding Paperboard Box Manufacturing |
| SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
| Sales Range | $1 M to 5M |
| # of Employees | 14 |
| Plant Area |
16,000
ft2
|
| Annual Production | 50,000
units
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Hawaii |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $27,080 | 318,461 |
kWh
|
$0.085 |
| Electricity Demand | $7,796 | 1,359 |
kW-mo/yr
|
$5.74 |
| Electricity Fees | $21,959 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,204 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4321: Upgrade obsolete equipment | $14,766 | $42,706 |
$12,509
72,305
kWh
|
$2,257
-
kW-mo/yr
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,107 | $3,180 |
$931
5,291
kWh
|
$176
-
kW-mo/yr
|
|
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,010 | - |
$856
4,946
kWh
|
$154
-
kW-mo/yr
|
|
| 04 | 2.6211: Conserve energy by efficient use of vending machines | $321 | $189 |
$321
1,825
kWh
|
- | |
| TOTAL RECOMMENDED | $17,204 | $46,075 |
$14,617
84,367
kWh
|
$2,587
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||