Assessment Year | 2007 |
---|---|
Principal Product | Kitchen and bath cabinets |
NAICS | 337110: Wood Kitchen Cabinet and Countertop Manufacturing |
SIC | 2434: Wood Kitchen Cabinets |
Sales Range | $50 M to 100M |
# of Employees | 750 |
Plant Area |
214,000
ft2
|
Annual Production | 250,000
pieces
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $347,812 | 6,157,271 |
kWh
|
$0.056 |
Electricity Demand | $51,423 | 15,405 |
kW-mo/yr
|
$3.34 |
Natural Gas | $269,513 | 24,732 |
MMBtu
|
$10.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,730 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $58,875 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $24,804 | $7,172 |
$24,804
442,135
kWh
|
- | - | - | - | |
02 | 2.5115: Reposition oven walls to reduce heated space | $15,876 | $4,452 |
$9,401
167,581
kWh
|
$1,557
-
kW-mo/yr
|
$4,918
-
MMBtu
|
- | - | |
03 | 2.2531: Re-size charging openings or add movable cover or door | $3,246 | $1,162 | - | - |
$3,246
-
MMBtu
|
- | - | |
04 | 2.6127: Maintain air filters by cleaning or replacement | $8,530 | $1,852 |
$5,667
101,021
kWh
|
- | - | $1,010 | $1,853 | |
05 | 2.4239: Eliminate or reduce compressed air usage | $9,388 | $2,619 |
$8,054
143,562
kWh
|
$1,334
-
kW-mo/yr
|
- | - | - | |
06 | 2.3212: Optimize plant power factor | $6,971 | $17,098 | - |
$6,971
-
kW-mo/yr
|
- | - | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $3,766 | $432 |
$3,232
57,626
kWh
|
$534
-
kW-mo/yr
|
- | - | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,795 | $398 |
$1,539
27,432
kWh
|
$256
-
kW-mo/yr
|
- | - | - | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $354 | $650 |
$338
6,023
kWh
|
$16
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $74,730 | $35,835 |
$53,035
945,380
kWh
|
$10,668
-
kW-mo/yr
|
$8,164
-
MMBtu
|
$1,010 | $1,853 | ||
TOTAL IMPLEMENTED | $58,875 | $16,235 |
$47,030
838,336
kWh
|
$3,681
-
kW-mo/yr
|
$8,164
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs