Assessment Year | 2024 |
---|---|
Principal Product | NA |
NAICS | 611210: Junior Colleges |
SIC | 8222: Junior Colleges and Technical Institutes |
Sales Range | less than $500 k |
# of Employees | 60 |
Plant Area |
151,110
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 5,840
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $49,484 | 1,364,860 |
kWh
|
$0.036 |
Electricity Demand | $72,956 | 4,591 |
kW-mo/yr
|
$15.89 |
Natural Gas | $84,401 | 6,974 |
MMBtu
|
$12.10 |
TOTAL YEARLY COSTS | $206,841 | |||
RECOMMENDED SAVINGS* | $57,821 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7311: Ventilation system to shut off when room is not in use | $26,630 | $43,200 |
$8,964
245,670
kWh
|
- | - |
$17,666
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,113 | $26,430 |
$6,282
106,069
kWh
|
$1,831
-
kW-mo/yr
|
- | - | - | |
03 | 2.8113: Purchase gas directly from a contract gas supplier | $22,211 | $18,400 | - | - | - | - | $22,211 | |
04 | 2.3212: Optimize plant power factor | $717 | $2,200 | - | - | $717 | - | - | |
05 | 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads | $150 | $450 |
$150
4,140
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $57,821 | $90,680 |
$15,396
355,879
kWh
|
$1,831
-
kW-mo/yr
|
$717 |
$17,666
-
MMBtu
|
$22,211 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs