| Assessment Year | 2024 |
|---|---|
| Principal Product | Compost |
| NAICS | 325314: Fertilizer (Mixing Only) Manufacturing |
| SIC | 2875: Fertilizers, Mixing Only |
| Sales Range | $1 M to 5M |
| # of Employees | 10 |
| Plant Area |
76,800
ft2
|
| Annual Production | 250,000
ton
|
| Production Hrs. Annual | 3,528
hrs
|
| Location (State) | Idaho |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $7,723 | 185,500 |
kWh
|
$0.042 |
| Electricity Demand | $4,050 | 810 |
kW-mo/yr
|
$5.00 |
| Electricity Fees | $434 | - |
|
- |
| Fuel Oil #2 | $105,476 | 31,650 |
MMBtu
|
$3.33 |
| Other Gas | $2,007 | 511 |
MMBtu
|
$3.93 |
| TOTAL YEARLY COSTS | $119,690 | |||
| RECOMMENDED SAVINGS* | $76,093 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $76,093 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.5196: Use small number of high output units instead of many small inefficient units | $19,754 | $108,000 | - | - |
$19,754
-
MMBtu
|
- | |
| 02 | 2.5196: Use small number of high output units instead of many small inefficient units | $53,389 | $212,000 | - | - |
$9,709
-
MMBtu
|
$43,680 | |
| 03 | 2.9114: Use solar heat to make electricty | $1,880 | $5,500 |
$1,610
38,550
kWh
|
$270
-
kW-mo/yr
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,070 | $4,410 |
$440
10,660
kWh
|
$630
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $76,093 | $329,910 |
$2,050
49,210
kWh
|
$900
-
kW-mo/yr
|
$29,463
-
MMBtu
|
$43,680 | ||
| TOTAL IMPLEMENTED | $76,093 | $329,910 |
$2,050
49,210
kWh
|
$900
-
kW-mo/yr
|
$29,463
-
MMBtu
|
$43,680 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs