Assessment Year | 2024 |
---|---|
Principal Product | Pre-Impregnanted Carbon Fiber |
NAICS | 335991: Carbon and Graphite Product Manufacturing |
SIC | 3624: Carbon and Graphite Products |
Sales Range | $100 M to 500M |
# of Employees | 500 |
Plant Area |
1,500,000
ft2
|
Annual Production | 200,000
thousand feet
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $973,527 | 33,596,906 |
kWh
|
$0.029 |
Electricity Demand | $88,792 | 5,570 |
kW-mo/yr
|
$15.94 |
Electricity Fees | $328,903 | - |
|
- |
Natural Gas | $1,698,070 | 181,990 |
MMBtu
|
$9.33 |
TOTAL YEARLY COSTS | $3,089,292 | |||
RECOMMENDED SAVINGS* | $240,993 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $188,553 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $139,774 | $4,000 |
$82,199
2,834,435
kWh
|
$57,575
-
kW-mo/yr
|
- | |
02 | 2.2153: Close off unneeded steam lines | $10,220 | $4,400 | - | - |
$10,220
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,164 | $37,300 |
$8,062
278,000
kWh
|
$6,102
-
kW-mo/yr
|
- | |
04 | 2.7135: Install occupancy sensors | $5,187 | $5,143 |
$2,891
99,700
kWh
|
$2,295
-
kW-mo/yr
|
- | |
05 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $8,004 | $11,422 |
$6,639
228,947
kWh
|
$1,365
-
kW-mo/yr
|
- | |
06 | 2.2622: Replace existing chiller with high efficiency model | $21,730 | $82,100 |
$15,800
543,000
kWh
|
$5,930
-
kW-mo/yr
|
- | |
07 | 2.7243: Improve air circulation with destratification fans / other methods | $6,520 | $9,510 |
$6,520
225,000
kWh
|
- | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,658 | $13,800 |
$6,116
210,884
kWh
|
$4,543
-
kW-mo/yr
|
- | |
09 | 2.4239: Eliminate or reduce compressed air usage | $12,487 | $68,600 |
$7,131
246,000
kWh
|
$5,356
-
kW-mo/yr
|
- | |
10 | 2.4321: Upgrade obsolete equipment | $12,250 | $84,300 |
$6,990
241,036
kWh
|
$5,260
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $240,993 | $320,575 |
$142,348
4,907,002
kWh
|
$88,425
-
kW-mo/yr
|
$10,220
-
MMBtu
|
||
TOTAL IMPLEMENTED | $188,553 | $154,053 |
$112,778
3,889,055
kWh
|
$75,775
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs