Assessment Year | 2022 |
---|---|
Principal Product | Aluminum |
NAICS | 331318: Other Aluminum Rolling, Drawing, and Extruding |
SIC | 3355: Aluminum Rolling and Drawing, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 245 |
Plant Area |
300,000
ft2
|
Annual Production | 130,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,532,829 | 25,031,995 |
kWh
|
$0.061 | |
Natural Gas | $1,966,616 | 479,243 |
MMBtu
|
$4.10 | |
Waste Disposal Costs | |||||
Water Usage | $166,894 | 44,917 |
Tgal
|
$3.72 | |
TOTAL YEARLY COSTS | $3,666,339 | ||||
RECOMMENDED SAVINGS* | $271,900 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $265,727 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Water Usage Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $139,892 | $110,800 |
$139,892
2,293,309
kWh
|
- | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $79,430 | $1,500 | - | $79,430 | - | |
03 | 4.454: Modify startup/shutdown times | $15,730 | $3,713 |
$15,730
257,861
kWh
|
- | - | |
04 | 2.8123: Pay utility bills on time | $23,515 | $750 | - | $23,515 | - | |
05 | 3.4151: Minimize water usage | $5,292 | $1,764 | - | - |
$5,292
-
Tgal
|
|
06 | 2.7124: Make a practice of turning off lights when not needed | $3,388 | $5,440 |
$3,388
55,503
kWh
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,868 | $1,019 |
$1,868
30,628
kWh
|
- | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,802 | $1,125 |
$1,802
29,534
kWh
|
- | - | |
09 | 2.4239: Eliminate or reduce compressed air usage | $983 | $375 |
$983
16,115
kWh
|
- | - | |
TOTAL RECOMMENDED | $271,900 | $126,486 |
$163,663
2,682,950
kWh
|
$102,945 |
$5,292
-
Tgal
|
||
TOTAL IMPLEMENTED | $265,727 | $119,546 |
$157,490
2,581,798
kWh
|
$102,945 |
$5,292
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Water Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs