| Assessment Year | 2020 |
|---|---|
| Principal Product | Degrees, certificates, and better futures. |
| NAICS | 611310: Colleges, Universities, and Professional Schools |
| SIC | 8221: Colleges, Universities, and Professional Schools |
| Sales Range | $1 M to 5M |
| # of Employees | 50 |
| Plant Area |
122,605
ft2
|
| Annual Production | 300
units
|
| Production Hrs. Annual | 3,400
hrs
|
| Location (State) | Utah |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $23,320 | 625,888 |
kWh
|
$0.037 |
| Electricity Demand | $53,161 | 3,414 |
kW-mo/yr
|
$15.57 |
| Natural Gas | $31,673 | 5,356 |
MMBtu
|
$5.91 |
| TOTAL YEARLY COSTS | $108,153 | |||
| RECOMMENDED SAVINGS* | $15,740 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,880 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7314: Reduce ventilation air | $7,045 | $7,045 |
$7,045
188,870
kWh
|
- | - | - | |
| 02 | 2.7314: Reduce ventilation air | $4,090 | $1,125 |
$1,700
46,120
kWh
|
$1,740
-
kW-mo/yr
|
$650
-
MMBtu
|
- | |
| 03 | 2.7226: Use computer programs to optimize hvac performance | $2,520 | $7,400 |
$780
21,073
kWh
|
- |
$2,940
-
MMBtu
|
$(-1,200.0) | |
| 04 | 2.7229: Air condition only space necessary | $1,220 | $1,500 |
$1,220
32,595
kWh
|
- | - | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $660 | $660 |
$660
17,780
kWh
|
- | - | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $205 | $660 |
$150
4,040
kWh
|
$55
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $15,740 | $18,390 |
$11,555
310,478
kWh
|
$1,795
-
kW-mo/yr
|
$3,590
-
MMBtu
|
$(-1,200.0) | ||
| TOTAL IMPLEMENTED | $1,880 | $2,160 |
$1,880
50,375
kWh
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs