Assessment Year 2020
Principal Product Degrees, certificates, and better futures.
NAICS 611310: Colleges, Universities, and Professional Schools
SIC 8221: Colleges, Universities, and Professional Schools
Sales Range $1
M
to 5
M
# of Employees 50
Plant Area 122,605
ft2
Annual Production 300
units
Production Hrs. Annual 3,400
hrs
Location (State) Utah

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $23,320 625,888
kWh
Electricity Demand $53,161 3,414
kW-mo/yr
Natural Gas $31,673 5,356
MMBtu
TOTAL YEARLY COSTS $108,153
RECOMMENDED SAVINGS* $15,740 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,880

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
01 2.7314: Reduce ventilation air $7,045 $7,045 $7,045
188,870
kWh
- - -
02 2.7314: Reduce ventilation air $4,090 $1,125 $1,700
46,120
kWh
$1,740
-
kW-mo/yr
$650
-
MMBtu
-
03 2.7226: Use computer programs to optimize hvac performance $2,520 $7,400 $780
21,073
kWh
- $2,940
-
MMBtu
$(-1,200.0)
04 2.7229: Air condition only space necessary $1,220 $1,500 $1,220
32,595
kWh
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $660 $660 $660
17,780
kWh
- - -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $205 $660 $150
4,040
kWh
$55
-
kW-mo/yr
- -
TOTAL RECOMMENDED $15,740 $18,390 $11,555
310,478
kWh
$1,795
-
kW-mo/yr
$3,590
-
MMBtu
$(-1,200.0)
TOTAL IMPLEMENTED $1,880 $2,160 $1,880
50,375
kWh
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs