Assessment Year | 2020 |
---|---|
Principal Product | Portland Cement |
NAICS | 327310: Cement Manufacturing |
SIC | 3241: Cement, Hydraulic |
Sales Range | $100 M to 500M |
# of Employees | 100 |
Plant Area |
100,000
ft2
|
Annual Production | 1,250,000
ton
|
Production Hrs. Annual | 8,250
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $3,639,188 | 112,390,000 |
kWh
|
$0.032 |
Electricity Demand | $2,535,070 | 187,640 |
kW-mo/yr
|
$13.51 |
Electricity Fees | $96,333 | - |
|
- |
TOTAL YEARLY COSTS | $6,270,592 | |||
RECOMMENDED SAVINGS* | $295,317 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $85,542 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $190,938 | $844,579 |
$145,559
4,495,343
kWh
|
$88,338
-
kW-mo/yr
|
$(-42,959.0) | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $47,066 | $8,500 |
$25,406
784,629
kWh
|
$21,659
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $38,476 | $12,000 |
$38,476
1,188,265
kWh
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $10,384 | $1,000 |
$6,462
199,568
kWh
|
$3,922
-
kW-mo/yr
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,454 | $16,900 |
$8,454
261,073
kWh
|
- | - | |
TOTAL RECOMMENDED | $295,317 | $882,979 |
$224,358
6,928,878
kWh
|
$113,918
-
kW-mo/yr
|
$(-42,959.0) | ||
TOTAL IMPLEMENTED | $85,542 | $20,500 |
$63,883
1,972,894
kWh
|
$21,659
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs