ITAC Assessment: LS0225
ITAC logo
ITAC Assessment: LS0225
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Refrigerated Warehousing and Storage
NAICS 493120: Refrigerated Warehousing and Storage
SIC 4222: Refrigerated Warehousing and Storage
Sales Range less than $500
k
# of Employees 125
Plant Area 84,315
ft2
Annual Production 1
units
Production Hrs. Annual 8,060
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $398,127 4,336,500
kWh
TOTAL YEARLY COSTS $398,127
RECOMMENDED SAVINGS* $51,090 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7211: Clean and maintain refrigerant condensers and towers $4,695 - $4,695
51,033
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $3,607 $2,927 $3,607
39,204
kWh
03 2.7425: Clean or color roof to reduce solar load $3,877 $29,510 $3,877
42,141
kWh
04 2.9114: Use solar heat to make electricty $38,911 $514,800 $38,911
422,948
kWh
TOTAL RECOMMENDED $51,090 $547,237 $51,090
555,326
kWh
TOTAL IMPLEMENTED - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs