| Assessment Year | 2017 |
|---|---|
| Principal Product | Water |
| NAICS | 221310: Water Supply and Irrigation Systems |
| SIC | 4941: Water Supply |
| Sales Range | $10 M to 50M |
| # of Employees | 19 |
| Plant Area |
291,850,000
ft2
|
| Annual Production | 802,145
Tgal
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Utah |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $75,887 | 1,742,135 |
kWh
|
$0.044 | |
| Waste Disposal Costs | |||||
| Water Usage | $254,280 | 802,145 |
Tgal
|
$0.32 | |
| TOTAL YEARLY COSTS | $330,167 | ||||
| RECOMMENDED SAVINGS* | $41,083 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $36,983 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Usage Savings |
|---|---|---|---|---|---|---|
| 01 | 3.4154: Eliminate leaks in water lines and valves | $22,871 | $23,400 | - |
$22,871
-
Tgal
|
|
| 02 | 3.1191: Change procedures / equipment / operating conditions | $7,624 | $13,970 | - |
$7,624
-
Tgal
|
|
| 03 | 3.4155: Meter waste water | $4,100 | - |
$4,100
94,130
kWh
|
- | |
| 04 | 2.4131: Size electric motors for peak operating efficiency | $3,374 | $5,770 |
$3,374
77,457
kWh
|
- | |
| 05 | 2.4131: Size electric motors for peak operating efficiency | $3,114 | $4,625 |
$3,114
71,498
kWh
|
- | |
| TOTAL RECOMMENDED | $41,083 | $47,765 |
$10,588
243,085
kWh
|
$30,495
-
Tgal
|
||
| TOTAL IMPLEMENTED | $36,983 | $47,765 |
$6,488
148,955
kWh
|
$30,495
-
Tgal
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs