Assessment Year 2017
Principal Product Dietary Supplements
NAICS 325411: Medicinal and Botanical Manufacturing
SIC 2833: Medicinal Chemicals and Botanical Products
Sales Range $50
M
to 100
M
# of Employees 200
Plant Area 18,800
ft2
Annual Production 13,000,000
units
Production Hrs. Annual 6,240
hrs
Location (State) Utah

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $52,332 1,327,204
kWh
Electricity Demand $45,680 3,694
kW-mo/yr
Electricity Fees $32,791 -
Natural Gas $16,521 1,974
MMBtu
Waste Disposal Costs
Water Usage $2,178 1,832
Tgal
TOTAL YEARLY COSTS $149,502
RECOMMENDED SAVINGS* $23,628 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,029

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Administrative Changes Savings By-product Production Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $5,742 $3,975 $2,562
65,700
kWh
$3,738
-
kW-mo/yr
$1,212 $(-1,770.3)
-
MMBtu
- -
02 2.3212: Optimize plant power factor $4,431 $4,250 - - $4,431 - - -
03 2.3131: Reschedule plant operations or reduce load to avoid peaks $4,428 - - $3,344
-
kW-mo/yr
$1,085 - - -
04 2.8113: Purchase gas directly from a contract gas supplier $2,918 - - - - - $2,918 -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,903 $2,472 $1,604
41,128
kWh
$979
-
kW-mo/yr
$320 - - -
06 2.1311: Replace electrically-operated equipment with fossil fuel equipment $1,324 $3,000 - - $1,324 - - -
07 3.5212: Regrind, reuse, or sell scrap plastic parts $1,100 - - - - - - $1,100
08 2.8112: Combine utility meters $657 $1,125 - - $657 - - -
09 2.7135: Install occupancy sensors $127 $240 $127
3,245
kWh
- - - - -
TOTAL RECOMMENDED $23,628 $15,062 $4,293
110,073
kWh
$8,061
-
kW-mo/yr
$9,027 $(-1,770.3)
-
MMBtu
$2,918 $1,100
TOTAL IMPLEMENTED $3,029 $2,712 $1,731
44,373
kWh
$979
-
kW-mo/yr
$320 - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Administrative Changes Savings By-product Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs