| Assessment Year | 2017 |
|---|---|
| Principal Product | Dietary Supplements |
| NAICS | 325411: Medicinal and Botanical Manufacturing |
| SIC | 2833: Medicinal Chemicals and Botanical Products |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
18,800
ft2
|
| Annual Production | 13,000,000
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Utah |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $52,332 | 1,327,204 |
kWh
|
$0.039 | |
| Electricity Demand | $45,680 | 3,694 |
kW-mo/yr
|
$12.37 | |
| Electricity Fees | $32,791 | - |
|
- | |
| Natural Gas | $16,521 | 1,974 |
MMBtu
|
$8.37 | |
| Waste Disposal Costs | |||||
| Water Usage | $2,178 | 1,832 |
Tgal
|
$1.19 | |
| TOTAL YEARLY COSTS | $149,502 | ||||
| RECOMMENDED SAVINGS* | $23,628 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $3,029 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | By-product Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $5,742 | $3,975 |
$2,562
65,700
kWh
|
$3,738
-
kW-mo/yr
|
$1,212 |
$(-1,770.3)
-
MMBtu
|
- | - | |
| 02 | 2.3212: Optimize plant power factor | $4,431 | $4,250 | - | - | $4,431 | - | - | - | |
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,428 | - | - |
$3,344
-
kW-mo/yr
|
$1,085 | - | - | - | |
| 04 | 2.8113: Purchase gas directly from a contract gas supplier | $2,918 | - | - | - | - | - | $2,918 | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,903 | $2,472 |
$1,604
41,128
kWh
|
$979
-
kW-mo/yr
|
$320 | - | - | - | |
| 06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,324 | $3,000 | - | - | $1,324 | - | - | - | |
| 07 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $1,100 | - | - | - | - | - | - | $1,100 | |
| 08 | 2.8112: Combine utility meters | $657 | $1,125 | - | - | $657 | - | - | - | |
| 09 | 2.7135: Install occupancy sensors | $127 | $240 |
$127
3,245
kWh
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $23,628 | $15,062 |
$4,293
110,073
kWh
|
$8,061
-
kW-mo/yr
|
$9,027 |
$(-1,770.3)
-
MMBtu
|
$2,918 | $1,100 | ||
| TOTAL IMPLEMENTED | $3,029 | $2,712 |
$1,731
44,373
kWh
|
$979
-
kW-mo/yr
|
$320 | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | By-product Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs