Assessment Year | 2006 |
---|---|
Principal Product | construction machinery |
NAICS | 333120: Construction Machinery Manufacturing |
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $100 M to 500M |
# of Employees | 709 |
Plant Area |
271,176
ft2
|
Annual Production | 1,500
pieces
|
Production Hrs. Annual | 4,940
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $125,731 | 4,815,840 |
kWh
|
$0.026 |
Electricity Demand | $142,776 | 12,968 |
kW-mo/yr
|
$11.01 |
Natural Gas | $124,722 | 19,081 |
MMBtu
|
$6.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $58,660 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $3,970 | $3,720 | - |
$3,970
-
kW-mo/yr
|
- | |
02 | 2.3191: Use demand controller or load shedder | $28,070 | $10,000 | - |
$28,070
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $14,560 | $2,670 |
$7,670
255,910
kWh
|
$6,890
-
kW-mo/yr
|
- | |
04 | 2.2437: Recover waste heat from equipment | $2,120 | $4,365 | - | - |
$2,120
-
MMBtu
|
|
05 | 2.4112: Install soft-start to eliminate nuisance trips | $9,940 | $30,000 |
$890
29,848
kWh
|
$9,050
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $58,660 | $50,755 |
$8,560
285,758
kWh
|
$47,980
-
kW-mo/yr
|
$2,120
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |