| Assessment Year | 2005 |
|---|---|
| Principal Product | Ice Cream Novelties |
| NAICS | 311520: Ice Cream and Frozen Dessert Manufacturing |
| SIC | 2024: Ice Cream and Frozen Desserts |
| Sales Range | $5 M to 10M |
| # of Employees | 40 |
| Plant Area |
61,800
ft2
|
| Annual Production | 24,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Utah |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $5,715 | 210,680 |
kWh
|
$0.027 |
| Electricity Demand | $8,885 | 884 |
kW-mo/yr
|
$10.05 |
| Natural Gas | $16,015 | 2,678 |
MMBtu
|
$5.98 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,420 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,140 | $380 |
$620
23,460
kWh
|
$520
-
kW-mo/yr
|
|
| 02 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,260 | $7,000 |
$1,260
47,420
kWh
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $370 | $220 |
$160
6,190
kWh
|
$210
-
kW-mo/yr
|
|
| 04 | 2.3191: Use demand controller or load shedder | $1,540 | - | - |
$1,540
-
kW-mo/yr
|
|
| 05 | 2.2515: Use optimum thickness insulation | $110 | $150 |
$110
4,112
kWh
|
- | |
| TOTAL RECOMMENDED | $4,420 | $7,750 |
$2,150
81,182
kWh
|
$2,270
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs