Assessment Year 2003
Principal Product cable and wire
NAICS 311520: Ice Cream and Frozen Dessert Manufacturing
SIC 3357: Drawing and Insulating of Nonferrous Wire
Sales Range $10
M
to 50
M
# of Employees 190
Plant Area 75,000
ft2
Annual Production 100,000
lb
Production Hrs. Annual 8,760
hrs
Location (State) Utah

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $428,947 15,464,800
kWh
Electricity Demand $284,180 384,192
kW-mo/yr
Natural Gas $74,597 17,019
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $58,587 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $9,352 $2,000 n/a - - $9,352
-
MMBtu
02 2.2414: Use waste heat from hot flue gases to preheat $1,207 $3,500 n/a - - $1,207
-
MMBtu
03 2.2511: Insulate bare equipment $1,080 $950 n/a - - $1,080
-
MMBtu
04 2.3212: Optimize plant power factor $31,340 $45,900 n/a - $31,340
-
kW-mo/yr
-
05 2.3131: Reschedule plant operations or reduce load to avoid peaks $14,860 - n/a - $14,860
-
kW-mo/yr
-
06 2.7121: Utilize daylight whenever possible in lieu of artificial light $748 - n/a $398
13,100
kWh
$350
-
kW-mo/yr
-
TOTAL RECOMMENDED $58,587 $52,350 $398
13,100
kWh
$46,550
-
kW-mo/yr
$11,639
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs